RF cable assemblies are often frequently handled and maneuvered into tight spaces. If not properly handled, it is common to see damage to the cable assembly, especially in the sensitive area just behind the cable connector, where it is terminated to the cable. SV Microwave has developed two different solutions to address this issue. One, our extended ferrule cable connectors is ideal for Ø.047" cable solutions, the other our RF strain relief boot features an external molded accessory that is incorporated into the assembly to prevent the cable from overbending. It can be used on both Ø.047" and Ø.085" cable types.
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles | 500 |
Mating Torque | 5 - 7 in - lbs |
Inter-mate ability | 2.4mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 50 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles | 500 |
Mating Torque | 5 - 7 in - lbs |
Inter-mate ability | 1.85mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 750 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | SMA |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz (select models to 26.5 GHz) |
Shielding Effectiveness | ≥ -90 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | 2.92mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles - SB | 1000 |
Mating Cycles - LD | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 3.0 lbs |
Insertion Force - LD | 5.0 lbs |
Insertion Force - FD | 7.0 lbs |
Withdrawal Force - SB | 0.5 lbs |
Withdrawal Force - LD | 7.0 lbs |
Withdrawal Force - FD | 9.0 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 2.5 lbs |
Insertion Force - FD | 4.5 lbs |
Withdrawal Force - SB | 1.5 lbs |
Withdrawal Force - FD | 6.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 250 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 1.2 lbs |
Insertion Force - FD | 2.5 lbs |
Withdrawal Force - SB | 1.0 lbs |
Withdrawal Force - FD | 4.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |